>Products>
  • SPECIFICATIONS
    Focus range/depth of field f4.7– 47mm/58cm-infinity
    Optical distortion -1.12% -+0.65%
    Dynamic range 100db
    SNR 50db above
    FOV Horizontal 62.5-6.43
    Sensor size CMOS 1/2.8”
    Standard Center Tripod mount ¼”/20 thread
    MJPEG Format 640×480, 1280×720, and 1920×1080 all at 30fps.
    Output USB2.0
    Receiver Dual IR
    Power Input 12V DC input at 2A
    Dimensions W 4 5/8” (117.5mm) , D 4 1/2" (112.7mm) , H 5 5/8” (143.2mm)
    Weight 1 lb 11oz (.77 Kg)
     
  • SPECIFICATIONS
    On-Device Display Illuminated Pictograms
    Image Resolution 500 ppi
    Image Grayscale 8 bit, 256
    Scanner Dimensions 6" x 6" x 6.1" (15.24 cm x 15.24 cm x 15.49 cm)
    Capture Platen 3.2" x 3.3" (15.24 cm x 15.24cm x 15.49 cm)
    Scanner Weight 3.3lbs (1.5kg)
    Operating Temperatures 32°F - 122°F (0°C - 50°C)
    Power Supply USB
    Operating Systems Windows® XP 32-bit; Windows® 7/8.1/10 32 and 64 bit
    Certifications FBI Appendix F, CE, FCC, UL, GS, REACH, RoHS
    Device Interface USB 2.0 High Speed
    Device Security Accepts Security Cable
      BIOMETRIC CAPTURE
    Fingerprint Flats and Rolls
    Capture Features Auto Capture, FlexFlats, FlexRolls, wet and dry finger image capture without pretreatment of hands or device recalibration
    Image Quality FBI Appendix F, Livescan, and ID Flats (with or without membrane)
    Optional Components Silicone pad, spoof detection, mounting bracket, cleaning kit
    Copyright © 2007 Cross Match Technologies, Inc. Specifications are subject to change without prior notice. L SCAN®, Crystal View™, Flash Capture™, Easy Control™, Perfect Roll™, Flash Capture True-1K™ and the Cross Match® logo are registered trademarks of Cross Match Technologies, Inc. Cross Match Technologies, Inc. acknowledges all trademarks used in this document and forbids the unauthorized use of any material contained herein.
  • SPECIFICATIONS
    Platen Dimensions 1.3” Vertical x .9” Horizontal
    Image Dimensions 1.0” Vertical x .8” Horizontal (500x400 Pixels)
    Geometric Distortion 1.5% or less
    Illumination Uniformity 3db or less at the edges and corners; Non-uniformity piecewise monotonic throughout
    Resolution 500dpi +/- 2%
    Grayscale Quantization 8 bits per pixel
  • SPECIFICATIONS
    On-Device Display Color LCD screen and smart buttons
    Capture Modes Auto Capture, FlexFlat, FlexRoll
    Image Quality Certification Livescan and ID Flats (with or without membrane); upper, lower and writers palm
    Image Resolution L Scan 500 - 500 ppi
    Image Dimentions Palm - 5.0" x 5.1" (127mmx 130mm) Rolled fingers - 1.5" x 1.6" (38mm x 41mm) ID flats - 3.0" x 3.2" (76mm x 81mm)
    Capture Grayscale 12 bit, 4096
    Image Grayscale 8 bit, 256
    Scanner Dimentions 12.0" x 12.1" x 5.2" (306mm x 308mm x 133mm)
    Capture Platen 5.9" x 5.51" (150mm x 140mm)
    Scanner Weight 16.72 lbs (7.2kg)
    Device Interface USB 3.0*
    Power Supply 100-240 v AC auto-adjusting; 50-60 Hz, 40 W maximum
    Heated Platen Consistent image quality regardless of ambient temperatures
    Operating Temperatures 32°F - 122°F (0°C - 50°C)
    Humidity Range Maximum 10% - 90% relative humidity, non-condensing
    Certifications FBI Appendix F, CE, FCC, UL, GS, REACH, RoHS
    Minimum Hardware Requirements Intel i3 Quad-core Processor with 1.8GHz, >= 4GB RAM
    Operating Systems Windows® 7, 8.1 and 10(32 and 64 bit)
    SDK L Scan Essentials 7.5 or later; L Scan Master
    Optional Components Adapter for Universal Cabinet, adapter for Adjustable Height Cabinet, foot pedal with USB interface, cleaning kit, silicone pad
    Copyright © 2007 Cross Match Technologies, Inc. Specifications are subject to change without prior notice. L SCAN®, Crystal View™, Flash Capture™, Easy Control™, Perfect Roll™, Flash Capture True-1K™ and the Cross Match® logo are registered trademarks of Cross Match Technologies, Inc. Cross Match Technologies, Inc. acknowledges all trademarks used in this document and forbids the unauthorized use of any material contained herein.
  • SPECIFICATIONS
    Dimensions (LxWxH) 133x66x18mm(5.2x2.6x0.7inches)
    Weight <150 grams (5.3 oz)
    Optical sensorn FBI PIV IQS certified, 500 dpi, 256 gray levels, 14x22 mm sensing area
    Display 2.4” QVGA color LCD
    Battery Li-ion, 1230 mAh
    Drop test 1.4m (4 ft)
    Ingress Protection IP32
    Operating conditions • Temperature: -10° to 50°C (14° to 122° F)
    • Humidity: 95% non-condensing
    Storage conditions -20° to 70°C (-4° to 158° F)
  • SPECIFICATIONS
    Compliant with standards FBI IAFIS-IQS, Appendix F, ANSI-NIST
    Resolution 500 dpi (horizontal and vertical)
    Dimension (L*W*H) 14x12.5x15.1cm (5.5x4.9x5.9")
    Slap print size 7, 8 x 8 (3.1 x 3.5")
    Rolled print size 3,8 x 4cm (1.5 x 1.6")
    Weight 1.9kg (4.18lb)
    EMC, Safety standards CE, FCC
    Other • RoHS compliant
    • The terminal has a MTBF in excess of 50,000 hours
     
  • SPECIFICATIONS
    Component Integration Cabinet houses a scanner, PC, UPS, keyboard, and has space on both sides of the scanner to hold or integrate smaller computer peripherals
    Supported Scanners Crossmatch Guardian 200, Crossmatch LScan 500, KOJAK NK110, Morpho TP5300, Morpho MorphoTop
    Scanner Integration The scanner is located 39" from the floor, which is the height recommended by ergonomic standards as well as the FBI. Scanner capture platen area is protected with a retractable plate covering the scanner top side when not in use
    Monitor 24" HDMI Display
    Keyboard Protection Locking hide-away keyboard tray for standard keyboards
    Mugshot Capture The optional mugshot Camera bracket allows for installation of camera for easy capture of mug shot, scar, mark and tattoo images
    Width (incl. work surface) 29" (737 mm)
    Height (w/ monitor) 67” (1701.8 mm)  - may vary
    Height (w/o monitor) 41.5" (1054.1 mm)
    Depth (incl. work surface) 27" (685.8 mm)
    Device Interface USB 2.0 High Speed
    Weight 220lbs (99.7 kg)
     
  • SPECIFICATIONS
    Scanning and Image Capture Resolution Scan Resolution: 1062 ppi (v) x 1638 ppi (h) Scan Depth: 8 bits/ pixel (256 gray levels) Capture Resolution: 1000 ppi (v) x 1000 ppi(h) Capture Depth: 8 bits/ pixel
    Active Image Dimensions Multi-Finger Plain: 3.2 (h) x 2.0(v) (nominal) inches Palm: 5.0 (h) x 5.1 (v) inches 10 Print Rolled: 1.6 (h) x 1.5 (v) inches ID Slap: 3.2 (h) x 3.0 (v) inches
    Image Quality Geometric Distortion: Exceeds FBI IQS specification without calibration Linearity, signal to Noise, CTF, Scanned gray levels: Meets or exceeds FBI IQS specifications
    Illumination While LED light panel for low operator eye fatigue and no color memory
    Scanner Data Interface USB 2.0
    Scanner Weight Approximately 20lbs (9 kg)
    Power Requirements 110-120/220-240 VAC, 50/60HZ/-less 15 watts, includes separate DC power module
    Operating Environment Ambient temperature: 40° – 104° F (5°-40° C) Relative humidity: 20-90% non-condensing AltitudeL 0-7500 ft (2460 m) AMSL
    Logical Scanner/ Host Interface Software Development Kit (SDK) includes application program interface and device drivers for Windows® XP, Windows® Vista, and Windows® 7 (Available for licensed developers)
    Balanced Image Distribution™ 200% less geometric distortion equals enhanced accuracy of minutiae and ridge detail location
    AntiSmear™ Technology Prevents smudging and smearing during finger rolls. High quality prints with less-skilled operators
    Auto Light Balancing Maintains Consistant image quality over time. Best Prints all the time.
  • SPECIFICATIONS
    USB Certification Spec USB-IF USB.ORG
    Power Source USB Host
    Ingress Protection IP65 Bezel To Film
    Humidity 30~85%%RH < 40C / 104F (Non-condensing)
    Scanner Assembly 2.36" x 2.44" x 1.30" / 60mm x 62mm x 33mm
    FCC/CE Conformance FCC Part 15 (per ANSI C62.4:2003) Class A, CSA ICES-003 Class A, CE Emissions: EN 55022:2006 Class A, CE Immunity EN 55024:1998/A1:2001/A2:2003, IEC 61000-4-2
    Certification Mobile ID IQS FAP 45, PIV, GSA FIPS 201, FBI Appendix F Certied
    Power Consumption • DC Current: <40mA idle, <250mA VBUS = +5.0VDC full scanning
    API Interface Capture Two Finger Direct and Single Finger Roll Image, Multi-device / Multi-thread support
    OS Support Windows 7, Windows 8.X, Windows XP, Windows Server, Windows Mobile 6.5, Linux, Android 4.0 (or higher)
    Surface Resistance Ammonia, IPA, Methanol, Soaps/detergents, Salt Water
    Vibration Test per MIL-STD-810F (Method 514.5), Category 24, Fig. 514.5C-17